Files
mRemoteNG/mRemoteV1/Connection/Connection.Protocol.PuttyBase.vb
2013-03-16 22:37:34 -05:00

287 lines
11 KiB
VB.net

Imports System.Runtime.InteropServices
Imports System.ComponentModel
Imports mRemoteNG.Messages
Imports mRemoteNG.App.Native
Imports System.Threading
Imports Microsoft.Win32
Imports System.Drawing
Imports mRemoteNG.App.Runtime
Imports System.Text.RegularExpressions
Imports mRemoteNG.Tools
Namespace Connection
Namespace Protocol
Public Class PuttyBase
Inherits Connection.Protocol.Base
#Region "Constants"
Private Const IDM_RECONF As Int32 = &H50 ' PuTTY Settings Menu ID
#End Region
#Region "Private Properties"
Dim _isPuttyNg As Boolean
#End Region
#Region "Public Properties"
Private _PuttyProtocol As Putty_Protocol
Public Property PuttyProtocol() As Putty_Protocol
Get
Return Me._PuttyProtocol
End Get
Set(ByVal value As Putty_Protocol)
Me._PuttyProtocol = value
End Set
End Property
Private _PuttySSHVersion As Putty_SSHVersion
Public Property PuttySSHVersion() As Putty_SSHVersion
Get
Return Me._PuttySSHVersion
End Get
Set(ByVal value As Putty_SSHVersion)
Me._PuttySSHVersion = value
End Set
End Property
Private _PuttyHandle As IntPtr
Public Property PuttyHandle() As IntPtr
Get
Return Me._PuttyHandle
End Get
Set(ByVal value As IntPtr)
Me._PuttyHandle = value
End Set
End Property
Private _PuttyProcess As Process
Public Property PuttyProcess() As Process
Get
Return Me._PuttyProcess
End Get
Set(ByVal value As Process)
Me._PuttyProcess = value
End Set
End Property
Private Shared _PuttyPath As String
Public Shared Property PuttyPath() As String
Get
Return _PuttyPath
End Get
Set(ByVal value As String)
_PuttyPath = value
End Set
End Property
'Private borderWidth As Integer = frmMain.Size.Width - frmMain.ClientSize.Width
'Private borderHeight As Integer = frmMain.Size.Height - frmMain.ClientSize.Height
Private Shared _BorderSize As Size
Public Shared Property BorderSize() As Size
Get
Return _BorderSize
End Get
Set(ByVal value As Size)
_BorderSize = value
End Set
End Property
Public ReadOnly Property Focused() As Boolean
Get
If GetForegroundWindow() = PuttyHandle Then
Return True
Else
Return False
End If
End Get
End Property
#End Region
#Region "Private Events & Handlers"
Private Sub ProcessExited(ByVal sender As Object, ByVal e As System.EventArgs)
MyBase.Event_Closed(Me)
End Sub
#End Region
#Region "Public Methods"
Public Sub New()
End Sub
Public Overrides Function Connect() As Boolean
Try
_isPuttyNg = IsFilePuttyNg(PuttyPath)
PuttyProcess = New Process
With PuttyProcess.StartInfo
.UseShellExecute = False
.FileName = _PuttyPath
Dim arguments As New CommandLineArguments
arguments.EscapeForShell = False
arguments.Add("-load", InterfaceControl.Info.PuttySession)
arguments.Add("-" & _PuttyProtocol.ToString)
If _PuttyProtocol = Putty_Protocol.ssh Then
Dim username As String = ""
Dim password As String = ""
If Not String.IsNullOrEmpty(InterfaceControl.Info.Username) Then
username = InterfaceControl.Info.Username
Else
If My.Settings.EmptyCredentials = "windows" Then
username = Environment.UserName
ElseIf My.Settings.EmptyCredentials = "custom" Then
username = My.Settings.DefaultUsername
End If
End If
If Not String.IsNullOrEmpty(InterfaceControl.Info.Password) Then
password = InterfaceControl.Info.Password
Else
If My.Settings.EmptyCredentials = "custom" Then
password = Security.Crypt.Decrypt(My.Settings.DefaultPassword, App.Info.General.EncryptionKey)
End If
End If
arguments.Add("-" & _PuttySSHVersion)
arguments.Add("-l", username)
arguments.Add("-pw", password)
End If
arguments.Add("-P", InterfaceControl.Info.Port.ToString)
arguments.Add(InterfaceControl.Info.Hostname)
If _isPuttyNg Then
arguments.Add("-hwndparent", InterfaceControl.Handle.ToString())
End If
.Arguments = arguments.ToString
End With
PuttyProcess.EnableRaisingEvents = True
AddHandler PuttyProcess.Exited, AddressOf ProcessExited
PuttyProcess.Start()
PuttyProcess.WaitForInputIdle(My.Settings.MaxPuttyWaitTime * 1000)
Dim startTicks As Integer = Environment.TickCount
While PuttyHandle.ToInt32 = 0 And Environment.TickCount < startTicks + (My.Settings.MaxPuttyWaitTime * 1000)
If _isPuttyNg Then
PuttyHandle = FindWindowEx(InterfaceControl.Handle, 0, vbNullString, vbNullString)
Else
PuttyProcess.Refresh()
PuttyHandle = PuttyProcess.MainWindowHandle
End If
If PuttyHandle.ToInt32 = 0 Then Thread.Sleep(0)
End While
If Not _isPuttyNg Then
SetParent(PuttyHandle, InterfaceControl.Handle)
End If
MessageCollector.AddMessage(MessageClass.InformationMsg, My.Language.strPuttyStuff, True)
MessageCollector.AddMessage(MessageClass.InformationMsg, String.Format(My.Language.strPuttyHandle, PuttyHandle.ToString), True)
MessageCollector.AddMessage(MessageClass.InformationMsg, String.Format(My.Language.strPuttyTitle, PuttyProcess.MainWindowTitle), True)
MessageCollector.AddMessage(MessageClass.InformationMsg, String.Format(My.Language.strPuttyParentHandle, InterfaceControl.Parent.Handle.ToString), True)
Resize(Me, New EventArgs)
MyBase.Connect()
Return True
Catch ex As Exception
MessageCollector.AddMessage(MessageClass.ErrorMsg, My.Language.strPuttyConnectionFailed & vbNewLine & ex.Message)
Return False
End Try
End Function
Public Overrides Sub Focus()
Try
If ConnectionWindow.InTabDrag Then Return
SetForegroundWindow(PuttyHandle)
Catch ex As Exception
MessageCollector.AddMessage(Messages.MessageClass.ErrorMsg, My.Language.strPuttyFocusFailed & vbNewLine & ex.Message, True)
End Try
End Sub
Public Overrides Sub Resize(ByVal sender As Object, ByVal e As EventArgs)
Try
If InterfaceControl.Size = Size.Empty Then Return
MoveWindow(PuttyHandle, -SystemInformation.FrameBorderSize.Width, -(SystemInformation.CaptionHeight + SystemInformation.FrameBorderSize.Height), InterfaceControl.Width + (SystemInformation.FrameBorderSize.Width * 2), InterfaceControl.Height + SystemInformation.CaptionHeight + (SystemInformation.FrameBorderSize.Height * 2), True)
Catch ex As Exception
MessageCollector.AddMessage(Messages.MessageClass.ErrorMsg, My.Language.strPuttyResizeFailed & vbNewLine & ex.Message, True)
End Try
End Sub
Public Overrides Sub Close()
Try
If PuttyProcess.HasExited = False Then
PuttyProcess.Kill()
End If
Catch ex As Exception
MessageCollector.AddMessage(Messages.MessageClass.ErrorMsg, My.Language.strPuttyKillFailed & vbNewLine & ex.Message, True)
End Try
Try
PuttyProcess.Dispose()
Catch ex As Exception
MessageCollector.AddMessage(Messages.MessageClass.ErrorMsg, My.Language.strPuttyDisposeFailed & vbNewLine & ex.Message, True)
End Try
MyBase.Close()
End Sub
Public Sub ShowSettingsDialog()
Try
PostMessage(Me.PuttyHandle, WM_SYSCOMMAND, IDM_RECONF, 0)
SetForegroundWindow(Me.PuttyHandle)
Catch ex As Exception
MessageCollector.AddMessage(Messages.MessageClass.ErrorMsg, My.Language.strPuttyShowSettingsDialogFailed & vbNewLine & ex.Message, True)
End Try
End Sub
#End Region
#Region "Public Shared Methods"
Public Shared Function IsFilePuttyNg(file As String) As Boolean
Dim isPuttyNg As Boolean
Try
isPuttyNg = FileVersionInfo.GetVersionInfo(file).InternalName.Contains("PuTTYNG")
Catch
isPuttyNg = False
End Try
Return isPuttyNg
End Function
Public Shared Sub StartPutty()
Try
Dim p As Process
Dim pSI As New ProcessStartInfo
pSI.FileName = PuttyPath
p = Process.Start(pSI)
p.WaitForExit()
Catch ex As Exception
MessageCollector.AddMessage(Messages.MessageClass.ErrorMsg, My.Language.strPuttyStartFailed & vbNewLine & ex.Message, True)
End Try
End Sub
#End Region
#Region "Enums"
Public Enum Putty_Protocol
ssh = 0
telnet = 1
rlogin = 2
raw = 3
serial = 4
End Enum
Public Enum Putty_SSHVersion
ssh1 = 1
ssh2 = 2
End Enum
#End Region
End Class
End Namespace
End Namespace