using System;
|
|
|
|
namespace S7.Net.Protocol
|
|
{
|
|
internal static class ConnectionRequest
|
|
{
|
|
public static byte[] GetCOTPConnectionRequest(CpuType cpu, Int16 rack, Int16 slot)
|
|
{
|
|
var tsapPair = GetDefaultTsapPair(cpu, rack, slot);
|
|
|
|
byte[] bSend1 = {
|
|
3, 0, 0, 22, //TPKT
|
|
17, //COTP Header Length
|
|
224, //Connect Request
|
|
0, 0, //Destination Reference
|
|
0, 46, //Source Reference
|
|
0, //Flags
|
|
193, //Parameter Code (src-tasp)
|
|
2, //Parameter Length
|
|
tsapPair.Local.FirstByte, tsapPair.Local.SecondByte, //Source TASP
|
|
194, //Parameter Code (dst-tasp)
|
|
2, //Parameter Length
|
|
tsapPair.Remote.FirstByte, tsapPair.Remote.SecondByte, //Destination TASP
|
|
192, //Parameter Code (tpdu-size)
|
|
1, //Parameter Length
|
|
10 //TPDU Size (2^10 = 1024)
|
|
};
|
|
|
|
return bSend1;
|
|
}
|
|
|
|
/// <summary>
|
|
/// Builds a <see cref="TsapPair" /> that can be used to connect to a PLC using the default connection
|
|
/// addresses.
|
|
/// </summary>
|
|
/// <remarks>
|
|
/// The remote TSAP is constructed using <code>new Tsap(0x03, (byte) ((rack << 5) | slot))</code>.
|
|
/// </remarks>
|
|
/// <param name="cpuType">The CPU type of the PLC.</param>
|
|
/// <param name="rack">The rack of the PLC's network card.</param>
|
|
/// <param name="slot">The slot of the PLC's network card.</param>
|
|
/// <returns>A TSAP pair that matches the given parameters.</returns>
|
|
/// <exception cref="ArgumentOutOfRangeException">The <paramref name="cpuType"/> is invalid.
|
|
///
|
|
/// -or-
|
|
///
|
|
/// The <paramref name="rack"/> parameter is greater than 15.
|
|
///
|
|
/// -or-
|
|
///
|
|
/// The <paramref name="slot"/> parameter is greater than 15.</exception>
|
|
public static TsapPair GetDefaultTsapPair(CpuType cpuType, int rack, int slot)
|
|
{
|
|
if (rack > 0x0F) throw InvalidRackOrSlot(rack, nameof(rack));
|
|
if (slot > 0x0F) throw InvalidRackOrSlot(slot, nameof(slot));
|
|
|
|
switch (cpuType)
|
|
{
|
|
case CpuType.S7200:
|
|
return new TsapPair(new Tsap(0x10, 0x00), new Tsap(0x10, 0x00));
|
|
case CpuType.Logo0BA8:
|
|
// The actual values are probably on a per-project basis
|
|
return new TsapPair(new Tsap(0x01, 0x00), new Tsap(0x01, 0x02));
|
|
case CpuType.S7200Smart:
|
|
case CpuType.S71200:
|
|
case CpuType.S71500:
|
|
case CpuType.S7300:
|
|
case CpuType.S7400:
|
|
// Testing with S7 1500 shows only the remote TSAP needs to match. This might differ for other
|
|
// PLC types.
|
|
return new TsapPair(new Tsap(0x01, 0x00), new Tsap(0x03, (byte) ((rack << 5) | slot)));
|
|
default:
|
|
throw new ArgumentOutOfRangeException(nameof(cpuType), "Invalid CPU Type specified");
|
|
}
|
|
}
|
|
|
|
private static ArgumentOutOfRangeException InvalidRackOrSlot(int value, string name)
|
|
{
|
|
return new ArgumentOutOfRangeException(name,
|
|
$"Invalid {name} value specified (decimal: {value}, hexadecimal: {value:X}), maximum value is 15 (decimal) or 0x0F (hexadecimal).");
|
|
}
|
|
}
|
|
}
|